The updated manual now includes a mandatory replacement of the rubber motor mounts if the centrifuge is used for qPCR prep (low vibration requirement). The old rubber compound hardens and transmits vibration after 8 years. Part 7: Frequently Asked Questions (Based on Real User Searches) Q1: Is there an updated Eppendorf 5402 manual in German ? Yes. The updated technical manual (Rev. 06) is bilingual (EN/DE). However, the quick-start guide is German-only (PN 5402-801). You can request the German service manual via Eppendorf’s legacy support portal. Q2: Can I use a 5424 rotor in my 5402? No. The updated manual explicitly lists only FA-45-18-11, F-45-30-11, and F-45-48-11 rotors. The 5424 uses a different spindle taper. Forcing a 5424 rotor will permanently damage the 5402’s motor shaft. Q3: My updated manual says "CE-DE" – what does that mean? This denotes "Compliance with German Emission Standards" (Deutsche Emissions). It was added to the updated manual in 2019 to reflect stricter EU noise directives (max 62 dBA for the 5402). No operational change is required. Q4: How do I download the service manual (not the user manual)? The full service manual (with circuit diagrams) is not publicly available due to Eppendorf IP. However, the updated User Manual includes an "Authorized Service Provider" section with wiring schematics for the power supply board (Pages 78-82). Part 8: The Future of the Eppendorf 5402 – Should You Upgrade? While the updated manual helps extend the life of your 5402, it also frankly lists operational limitations that newer centrifuges solve:
| Frequency | Task (from updated manual) | Consumable/Part | | :--- | :--- | :--- | | | Clean rotor chamber with ethanol (70%); wipe lid seal. | Lint-free wipe | | Monthly | Inspect rotor lid O-rings for cracking; lubricate with Eppendorf grease (No. 5810 310.008). | Silicone grease | | Quarterly | Measure rotor runout (max 0.1 mm). Check motor carbon brush length (<5 mm = replace). | Carbon brushes (2x) | | Annually | RPM calibration using a tachometer (Offset ±2% max). | Calibration sticker | | Every 5 years | Replace lid lock solenoid and all rubber feet. | Service kit SK-5402 | eppendorf 5402 manual updated
Avoid third-party PDF repositories. Many host a corrupted or pre-2005 version that lacks critical rotor life warnings. Part 3: What’s New in the Updated Manual? (Key Changes) If you currently have an old printed manual, here is a table of the most significant changes found in the updated 5402 documentation. The updated manual now includes a mandatory replacement
Search the official Eppendorf Technical Support forum using the tag #Eppendorf5402Update or contact their legacy equipment team directly – they still support this legendary centrifuge. Disclaimer: This article is a user-generated guide intended to supplement the official manufacturer documentation. Always refer to the original Eppendorf safety instructions before performing maintenance or operation. Eppendorf and 5402 are registered trademarks of Eppendorf AG. However, the quick-start guide is German-only (PN 5402-801)
For decades, the has been a workhorse in laboratories around the globe—from academic research centers to high-throughput clinical testing facilities. Known for its robust refrigeration system and reliable centrifugation of DNA, RNA, and protein samples, the 5402 remains in active use despite being succeeded by newer models like the 5424 and 5425 series.
| Feature | Eppendorf 5402 | Modern Replacement (e.g., 5425) | | :--- | :--- | :--- | | | 15 min to 4°C | 4 min to 4°C | | Noise level | 58-62 dBA | 48 dBA | | Rotor swap | Tool required | Tool-free ClickSpin | | Documentation | Legacy PDF (updated 2020) | Interactive QR code manual + video |